Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

OBJECTIVE: To investigate glycemic and psychosocial outcomes with hybrid closed-loop (HCL) versus user-determined insulin dosing with multiple daily injections (MDI) or insulin pump (i.e., standard therapy for most adults with type 1 diabetes). RESEARCH DESIGN AND METHODS: Adults with type 1 diabetes using MDI or insulin pump without continuous glucose monitoring (CGM) were randomized to 26 weeks of HCL (Medtronic 670G) or continuation of current therapy. The primary outcome was masked CGM time in range (TIR; 70-180 mg/dL) during the final 3 weeks. RESULTS: Participants were randomized to HCL (n = 61) or control (n = 59). Baseline mean (SD) age was 44.2 (11.7) years, HbA1c was 7.4% (0.9%) (57 [10] mmol/mol), 53% were women, and 51% used MDI. HCL TIR increased from (baseline) 55% (13%) to (26 weeks) 70% (10%) with the control group unchanged: (baseline) 55% (12%) and (26 weeks) 55% (13%) (difference 15% [95% CI 11, 19]; P < 0.0001). For HCL, HbA1c was lower (median [95% CI] difference -0.4% [-0.6, -0.2]; -4 mmol/mol [-7, -2]; P < 0.0001) and diabetes-specific positive well-being was higher (difference 1.2 [95% CI 0.4, 1.9]; P < 0.0048) without a deterioration in diabetes distress, perceived sleep quality, or cognition. Seventeen (9 device-related) versus 13 serious adverse events occurred in the HCL and control groups, respectively. CONCLUSIONS: In adults with type 1 diabetes, 26 weeks of HCL improved TIR, HbA1c, and their sense of satisfaction from managing their diabetes compared with those continuing with user-determined insulin dosing and self-monitoring of blood glucose. For most people living with type 1 diabetes globally, this trial demonstrates that HCL is feasible, acceptable, and advantageous.

Original publication

DOI

10.2337/dc20-1447

Type

Journal

Diabetes Care

Publication Date

12/2020

Volume

43

Pages

3024 - 3033

Keywords

Adult, Aged, Blood Glucose, Blood Glucose Self-Monitoring, Blood Specimen Collection, Diabetes Mellitus, Type 1, Female, Fingers, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Injections, Insulin, Insulin Infusion Systems, Male, Middle Aged, Needlestick Injuries, Personal Satisfaction